SURVIVAL FOLLOWING IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION IN PATIENTS WITH CARDIAC AMYLOIDOSIS
Higgins A, Annapureddy A, Wang Y, Minges K, Lampert R, Rosenfeld L, Jacoby D, Curtis J, Miller E, Freeman J. SURVIVAL FOLLOWING IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION IN PATIENTS WITH CARDIAC AMYLOIDOSIS. Journal Of The American College Of Cardiology 2019, 73: 694. DOI: 10.1016/s0735-1097(19)31302-6.Peer-Reviewed Original ResearchImplantable cardioverter defibrillator implantationCardioverter-defibrillator implantationCardiac amyloidosisPatientsAmyloidosisSURVIVAL FOLLOWING IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION IN PATIENTS WITH CARDIAC SARCOIDOSIS
Higgins A, Annapureddy A, Wang Y, Minges K, Lampert R, Rosenfeld L, Jacoby D, Curtis J, Miller E, Freeman J. SURVIVAL FOLLOWING IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR IMPLANTATION IN PATIENTS WITH CARDIAC SARCOIDOSIS. Journal Of The American College Of Cardiology 2019, 73: 306. DOI: 10.1016/s0735-1097(19)30914-3.Peer-Reviewed Original ResearchImplantable cardioverter defibrillator implantationCardioverter-defibrillator implantationCardiac sarcoidosisSarcoidosisPatients
2011
Dual-Chamber Implantable Cardioverter-Defibrillator Selection Is Associated With Increased Complication Rates and Mortality Among Patients Enrolled in the NCDR Implantable Cardioverter-Defibrillator Registry
Dewland TA, Pellegrini CN, Wang Y, Marcus GM, Keung E, Varosy PD. Dual-Chamber Implantable Cardioverter-Defibrillator Selection Is Associated With Increased Complication Rates and Mortality Among Patients Enrolled in the NCDR Implantable Cardioverter-Defibrillator Registry. Journal Of The American College Of Cardiology 2011, 58: 1007-1013. PMID: 21867834, DOI: 10.1016/j.jacc.2011.04.039.Peer-Reviewed Original ResearchConceptsDual-chamber ICDHospital mortalityComplication rateDevice implantationDual-chamber implantable cardioverter-defibrillator (ICD) implantationNational Cardiovascular Data Registry ICD RegistryImplantable Cardioverter-Defibrillator RegistrySingle-chamber ICD implantationImplantable cardioverter defibrillator implantationHospital complication ratesSingle-chamber defibrillatorsCardioverter-defibrillator implantationMajority of patientsReal-world populationDual-chamber devicesSingle-chamber devicesLongitudinal cohort designMedical comorbiditiesPeriprocedural complicationsAdverse eventsBaseline characteristicsICD implantationICD indicationICD RegistryICD useImplantable Cardioverter-Defibrillator Registry Risk Score Models for Acute Procedural Complications or Death After Implantable Cardioverter-Defibrillator Implantation
Haines DE, Wang Y, Curtis J. Implantable Cardioverter-Defibrillator Registry Risk Score Models for Acute Procedural Complications or Death After Implantable Cardioverter-Defibrillator Implantation. Circulation 2011, 123: 2069-2076. PMID: 21537001, DOI: 10.1161/circulationaha.110.959676.Peer-Reviewed Original ResearchConceptsImplantable cardioverter defibrillator implantationSimple risk scoreCardioverter-defibrillator implantationAdverse eventsRisk scoreLower riskNew York Heart Association class IIILow-risk subsetPrior valve surgeryAcute procedural complicationsChronic lung diseaseRisk stratification schemaAvailable clinical variablesBlood urea nitrogenIntensity of careRisk score modelLogistic regression modelsHospital complicationsAcute complicationsHospital deathValve surgeryICD implantationPostprocedural complicationsICD RegistryProcedural complications