2023
Characterization of GafchromicTM EBT4 film with clinical kV/MV photons and MeV electrons
Guan F, Chen H, Draeger E, Li Y, Aydin R, Tien C, Chen Z. Characterization of GafchromicTM EBT4 film with clinical kV/MV photons and MeV electrons. Precision Radiation Oncology 2023, 7: 84-91. DOI: 10.1002/pro6.1204.Peer-Reviewed Original ResearchX-ray beamMeV electron beamMV photon beamElectron beamMV photonsBeam energyMeV electronsPhoton beamsEnergy dependenceKilovoltage x-ray beamsMinimal energy dependenceClinical photonPhotonsBeamRadiation typesMeVElectronsDependence experimentsFilmsDose-response dependenceResponse dependenceDependenceEnergyNoise ratioEBT3
2022
PHSOR05 Presentation Time: 12:50 PM The Effect of Quantum Noise on a Novel Multilateration-Based Brachytherapy Source Localization Approach
Jensen P, Tien C, Chen Z. PHSOR05 Presentation Time: 12:50 PM The Effect of Quantum Noise on a Novel Multilateration-Based Brachytherapy Source Localization Approach. Brachytherapy 2022, 21: s25-s26. DOI: 10.1016/j.brachy.2022.09.023.Peer-Reviewed Original ResearchQuantum noiseSource positionAcquisition timePixel sizePhoton-counting systemParticle detectorsImage fluxesLarge pixel sizeDominant sourceAchievable resolutionPhysics principlesSource strengthAxis displacementCamera systemPoint sourcesParameter rangeSingle camera systemSecond cameraDose reconstructionSystem setupRadiation doseCentral axisDual-camera systemPhotonsSetup
2008
Ice as a water-equivalent solid medium for brachytherapy dosimetric measurements
Song H, Chen Z, Yue N, Wu Q, Yin FF. Ice as a water-equivalent solid medium for brachytherapy dosimetric measurements. Radiation And Environmental Biophysics 2008, 48: 145-151. PMID: 19066926, DOI: 10.1007/s00411-008-0205-9.Peer-Reviewed Original ResearchConceptsSolid phantomWater conversion factorNon-negligible uncertaintiesMono-energetic photonsPrecise positioningLow-energy photon-emitting brachytherapy sourcesChemical compositionBrachytherapy sourcesPositioning advantageDosimetric measurementsExperimental determinationNecessary precisionDosimetric characteristicsPhantomIceBrachytherapy dosimetryPositioningConversion factorPhotonsUncertaintyKeV
2007
Photon spectrometry for the determination of the dose‐rate constant of low‐energy photon‐emitting brachytherapy sources
Chen ZJ, Nath R. Photon spectrometry for the determination of the dose‐rate constant of low‐energy photon‐emitting brachytherapy sources. Medical Physics 2007, 34: 1412-1430. PMID: 17500473, DOI: 10.1118/1.2713217.Peer-Reviewed Original ResearchConceptsPhoton spectrometry techniquePhoton spectrometryHigh-resolution gamma-ray spectrometerDosimetry techniquesLow-energy photonsPhoton energy spectrumMono-energetic photonsGamma-ray spectrometerLow-energy photon-emitting brachytherapy sourcesBrachytherapy sourcesLow-energy sourcesAbsolute dosimeterPhoton characteristicsEnergy dependenceDetector sensitivityDetector sizeSolid phantomDose rate measurementsPhotonsDosimetric propertiesRadiation dosimetryDose rate constantDose rateSpectrometry techniquesAccurate measurement
2006
Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams
Ahmad M, Chen Z, Song H, Deng J, Nath R. Evaluation of the EDR-2 film for relative dosimetry of high-energy photon and electron beams. Radiation Protection Dosimetry 2006, 120: 159-162. PMID: 16644932, DOI: 10.1093/rpd/ncj006.Peer-Reviewed Original ResearchConceptsEDR-2 filmsElectron beamRelative dosimetryHigh-energy photonsClinical radiation dosimetryDose profilesPhotonsRadiation dosimetryBeamDose distributionRadiographic filmsSensitometric studyFilmsDosimetryTreatment planning techniquesElectronsDiodesSymmetryKVFlatnessPlanning techniquesDistribution