2022
Double pigtail stent placement as an adjunct to lumen-apposing metal stents for drainage of pancreatic fluid collections may not affect outcomes: A multicenter experience
Shamah SP, Sahakian AB, Chapman CG, Buxbaum JL, Muniraj T, Aslanian HA, Villa E, Cho J, Haider HI, Waxman I, Siddiqui UD. Double pigtail stent placement as an adjunct to lumen-apposing metal stents for drainage of pancreatic fluid collections may not affect outcomes: A multicenter experience. Endoscopic Ultrasound 2022, 11: 53-58. PMID: 35102901, PMCID: PMC8887040, DOI: 10.4103/eus-d-21-00030.Peer-Reviewed Original ResearchDouble-pigtail plastic stentsLumen-apposing metal stentsEUS-guided drainagePancreatic fluid collectionsAdverse eventsFluid collectionMetal stentsUS tertiary referral centersHigher adverse event ratesMulticenter retrospective studyTertiary referral centerAdverse event ratesOverall technical successTypes of PFCsPigtail plastic stentsPostsurgical fluid collectionReintervention rateMulticenter experienceReferral centerClinical outcomesRetrospective studyMulticenter studyStent placementTechnical successSubgroup analysis
2021
Novel 15-mm-long lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections located ≥10 mm from the luminal wall
Zhang LY, Kunda R, Aerts M, Messaoudi N, Pawa R, Pawa S, Robles-Medranda C, Oleas R, Al-Haddad MA, Obaitan I, Muniraj T, Fabbri C, Binda C, Anderloni A, Tarantino I, Bejjani M, Ghandour B, Singh V, Khashab MA. Novel 15-mm-long lumen-apposing metal stent for endoscopic ultrasound-guided drainage of pancreatic fluid collections located ≥10 mm from the luminal wall. Endoscopy 2021, 54: 706-711. PMID: 34905796, DOI: 10.1055/a-1682-7095.Peer-Reviewed Original ResearchConceptsDrainage of PFCsLumen-apposing metal stentsPancreatic fluid collectionsFluid collectionClinical successLuminal wallEndoscopic ultrasound-guided drainageUltrasound-guided drainageEUS-guided drainageLumen-apposing metalPrimary outcomeSecondary outcomesMulticenter studyTechnical successDuodenal wallEndoscopic ultrasoundMaximal diameterMetal stentsLAMS placementComplicationsPatientsRecurrenceOutcomesDrainagePresent outcomes
2020
Su1260 ENDOSCOPIC ULTRASOUND GUIDED GALLBLADDER DRAINAGE (EUS-GBD) WITH LUMEN APPOSING METAL STENTS (LAMS) IN PATIENTS WITH ACUTE CHOLECYSTITIS HAS EXCELLENT LONG-TERM OUTCOMES: A LARGE, MULTICENTER US STUDY
David Y, Kakked G, Dixon R, Confer B, Shah R, Khara H, Diehl D, Krafft M, Shah-Khan S, Nasr J, Benias P, Trindade A, Muniraj T, Aslanian H, Chahal P, Rodriguez J, Adler D, Dubroff J, DeLatour R, Tzimas D, Khanna L, Haber G, Goodman A, Hoerter N, Pandey N, Bakhit M, Kowalski T, Loren D, Chiang A, Schlachterman A, Nieto J, Deshmukh A, Ichkhanian Y, Halabi M, Khashab M, Kwon R, Prabhu A, Hernandez A, Storm A, Levy M, Miller C, Berzin T, Kushnir V, Cosgrove N, Mullady D, Al-Shahrani A, Rolston V, D'Souza L, Buscaglia J, Bucobo J, Kedia P, Kasmin F, Nagula S, Kumta N, DiMaio C. Su1260 ENDOSCOPIC ULTRASOUND GUIDED GALLBLADDER DRAINAGE (EUS-GBD) WITH LUMEN APPOSING METAL STENTS (LAMS) IN PATIENTS WITH ACUTE CHOLECYSTITIS HAS EXCELLENT LONG-TERM OUTCOMES: A LARGE, MULTICENTER US STUDY. Gastrointestinal Endoscopy 2020, 91: ab298-ab299. DOI: 10.1016/j.gie.2020.03.2106.Peer-Reviewed Original Research
2018
Safety and rate of delayed adverse events with lumen-apposing metal stents (LAMS) for pancreatic fluid collections: a multicenter study
Yang D, Perbtani Y, Mramba L, Kerdsirichairat T, Prabhu A, Manvar A, Ho S, Pannu D, Keswani R, Strand D, Wang A, Quintero E, Buscaglia J, Muniraj T, Aslanian H, Draganov P, Siddiqui A. Safety and rate of delayed adverse events with lumen-apposing metal stents (LAMS) for pancreatic fluid collections: a multicenter study. Endoscopy International Open 2018, 06: e1267-e1275. PMID: 30302385, PMCID: PMC6175687, DOI: 10.1055/a-0732-502.Peer-Reviewed Original ResearchLumen-apposing metal stentsPancreatic fluid collectionsAdverse eventsTreatment failureStent occlusionFluid collectionMetal stentsLogistic regressionMulticenter retrospective analysisProcedure-related factorsSymptomatic pancreatic fluid collectionsConsecutive patientsMulticenter studyEndoscopic ultrasoundEndoscopic drainageLower incidenceRetrospective analysisMAIN OUTCOMELAMS removalPatientsPFC resolutionLAMS placementOnly factorSole predictorStents