2024
Developing an alternative calorimeter solution for the future Muon Collider: The Crilin design
Cantone C, Cemmi A, Ceravolo S, Ciccarella V, Colao F, Di Meco E, Di Sarcina I, Diociaiuti E, Gargiulo R, Gianotti P, Giraldin C, Leonardi E, Lucchesi D, Moulson M, Paesani D, Pastrone N, Pezzullo G, Saputi A, Sarra I, Scifo J, Sestini L, Soldani M, Tagnani D, Verna A, Zuliani D. Developing an alternative calorimeter solution for the future Muon Collider: The Crilin design. Nuclear Instruments And Methods In Physics Research Section A Accelerators Spectrometers Detectors And Associated Equipment 2024, 1069: 169973. DOI: 10.1016/j.nima.2024.169973.Peer-Reviewed Original ResearchBeam-induced backgroundMuon colliderElectromagnetic calorimeterSilicon photo-multipliersBeam Test FacilityExcellent time resolutionBeam testFuture collidersGeV electronsMeV electronsPhoto-multipliersRadiation toleranceIrradiation campaignColliderPbF 2Time resolutionLead fluorideMuonBeamCalorimeterElectronLongitudinal segmentsGeVMeVTest facilityResearch and Development Status for an Innovative Crystal Calorimeter for the Future Muon Collider
Cantone C, Ceravolo S, Colao F, Di Meco E, Diociaiuti E, Frank I, Gianotti P, Gargiulo R, Leonardi E, Lucchesi D, Martellotti S, Moulson M, Paesani D, Pastrone N, Pezzullo G, Saputi A, Sarra I, Sestini L, Tagnani D. Research and Development Status for an Innovative Crystal Calorimeter for the Future Muon Collider. IEEE Transactions On Nuclear Science 2024, 71: 1116-1123. DOI: 10.1109/tns.2024.3364771.Peer-Reviewed Original ResearchBeam-induced backgroundSuperior energy resolutionEvent reconstruction algorithmsBeam Test FacilityHarsh radiation environmentLead fluoride crystalsMuon colliderCrystal calorimeterEnergy resolutionElectromagnetic calorimeterEnergy precisionMeV electronsSilicon photomultipliersNeutron fluxIonizing doseRadiation environmentRadiation toleranceIrradiation campaignDesign detectorsFluoride crystalsMuonBeam testHigher granularityTest beamParticle jets
2020
The Mu2e e.m. Calorimeter: Crystals and SiPMs Production Status
Atanov N, Baranov V, Budagov J, Caiulo D, Cervelli F, Colao F, Cordelli M, Corradi M, Davydov Y, Di Falco S, Diociaiuti E, Donati S, Donghia R, Echenard B, Giovannella S, Glagolev V, Grancagnolo F, Happacher F, Hitlin D, Martini M, Miscetti S, Miyashita T, Morescalchi L, Murat P, Pedreschi E, Pezzullo G, Porter F, Raffaelli F, Ricci M, Saputi A, Sarra I, Spinella F, Tassielli G, Tereshchenko V, Usubov Z, Vasilyev I, Zhu R. The Mu2e e.m. Calorimeter: Crystals and SiPMs Production Status. IEEE Transactions On Nuclear Science 2020, 67: 978-982. DOI: 10.1109/tns.2020.2988422.Peer-Reviewed Original ResearchCrystal readoutExcellent particle identification capabilitiesParticle identification capabilitiesNeutrino-less conversionTrack reconstruction capabilityBeam Test FacilityCosmic raysEnergy resolutionMu2e experimentLarge acceptanceElectromagnetic calorimeterSilicon photomultipliersNegative muonsPosition resolutionLepton flavorAluminum nucleiTime resolutionCalorimeter designMm2 dimensionsLarge-scale prototypeIdentification capabilityMeVElectronsReconstruction capabilitiesReadout
2018
Design and Status of the Mu2e Crystal Calorimeter
Atanov N, Baranov V, Budagov J, Davydov Y, Glagolev V, Tereshchenko V, Usubov Z, Cervelli F, Di Falco S, Donati S, Morescalchi L, Pedreschi E, Pezzullo G, Raffaelli F, Spinella F, Colao F, Cordelli M, Corradi G, Diociaiuti E, Donghia R, Giovannella S, Happacher F, Martini M, Miscetti S, Ricci M, Saputi A, Sarra I, Echenard B, Hitlin D, Miyashita T, Porter F, Zhu R, Grancagnolo F, Tassielli G, Murat P. Design and Status of the Mu2e Crystal Calorimeter. IEEE Transactions On Nuclear Science 2018, 65: 2073-2080. DOI: 10.1109/tns.2018.2790702.Peer-Reviewed Original ResearchEnergy resolutionParticle identification capabilitiesHarsh radiation environmentBeam Test FacilityAxial magnetic fieldLarge-area arraysCosmic raysNew physicsMonoenergetic electronsCrystal calorimeterRest massEnergy rangeElectron beamMu2e experimentElectromagnetic calorimeterLarge acceptanceRadiation environmentSilicon photomultipliersNegative muonsPosition resolutionLepton flavorAluminum nucleiMagnetic fieldNormal incidenceTime resolution
2017
Measurement of the energy and time resolution of a undoped CsI + MPPC array for the Mu2e experiment
Atanova O, Cordelli M, Corradi G, Colao F, Davydov Y, Donghia R, Di Falco S, Giovannella S, Happacher F, Martini M, Miscetti S, Morescalchi L, Murat P, Pezzullo G, Saputi A, Sarra I, Soleti S, Tagnani D, Tereshchenko V, Usubov Z. Measurement of the energy and time resolution of a undoped CsI + MPPC array for the Mu2e experiment. Journal Of Instrumentation 2017, 12: p05007-p05007. DOI: 10.1088/1748-0221/12/05/p05007.Peer-Reviewed Original Research
2016
Measurement of time resolution of the Mu2e LYSO calorimeter prototype
Atanov N, Baranov V, Colao F, Cordelli M, Corradi G, Dané E, Davydov Y, Flood K, Giovannella S, Glagolev V, Happacher F, Hitlin D, Martini M, Miscetti S, Miyashita T, Morescalchi L, Pezzullo G, Saputi A, Sarra I, Soleti S, Tassielli G, Tereshchenko V. Measurement of time resolution of the Mu2e LYSO calorimeter prototype. Nuclear Instruments And Methods In Physics Research Section A Accelerators Spectrometers Detectors And Associated Equipment 2016, 812: 104-111. DOI: 10.1016/j.nima.2015.12.055.Peer-Reviewed Original Research