Skip to Main Content

Three-dimensional printing versus freehand surgical techniques in the surgical management of adolescent idiopathic spinal deformity

October 07, 2022

Journal: Journal of Spine Surgery

Who: William M. McLaughlin, Claire A. Donnelley, Kristin Yu, Stephen M. Gillinov, Dominick A. Tuason

Overview: Three-dimensional (3D) printed guides are finding increasing applications in the field of orthopaedic surgery and more recently spine surgery. This retrospective cohort study compares benefits and costs of 3D printed guides in surgical treatment of adolescent idiopathic scoliosis (AIS) compared to freehand techniques.

Intraoperative screw placement was conducted either with 3D printed guides (3D cohort) or traditional freehand technique (freehand cohort) for AIS patients undergoing spinal fusion at a single institution. Patient and perioperative data include: screw placement time, length of surgery, blood loss, hospital stay, spinal curvature correction, total implant costs and training level of surgical assist. Multivariate analysis assessed for confounding and effect modification. P-values <0.05 were considered significant.

There were 29 patients included in analyses, 18 in the 3D and 11 in the freehand (FH) cohort, for a total of 263 3D and 307 freehand screws. Between cohorts, there were no significant differences in patient age (P=0.93), gender (P=0.15), height (P=0.18) or weight (P=0.40). The 3D cohort (mean $26,215, SD =$6,374) had significantly higher implant costs than FH (mean $18,660, SD =$5,587, P=0.003) with significantly reduced intraoperative blood loss (mean 559 mL, SD =273 FH; vs. mean 357 mL, SD =123 3D; P=0.01). On multivariate analysis, surgical residents had significantly faster screw placement times when using 3D guides (P<0.001) than when placing screws freehand. There were no significant differences between cohorts in length of postoperative hospitalization, spinal levels fused, or coronal or sagittal curve correction.

At significant cost, 3D printed guides reduce intraoperative blood loss compared to freehand pedicle screw placement and reduce screw placement time for surgical residents.

Submitted by John Ready on October 07, 2022