2023
Imaging Findings on Head Computed Tomography Scans in Victims of Intimate Partner Violence
Watane G, Tang A, Thomas R, Park H, Gujrathi R, Gosangi B, Khurana B. Imaging Findings on Head Computed Tomography Scans in Victims of Intimate Partner Violence. Journal Of Computer Assisted Tomography 2023, 47: 307-314. PMID: 36790916, DOI: 10.1097/rct.0000000000001427.Peer-Reviewed Original ResearchConceptsSoft tissue injuriesHead CTInjury visitsIntimate partner violenceTissue injurySubsequent injuryHead computed tomography (CT) scanLeft-sided injuriesInstitutional review board-approved retrospective analysisTime of injurySoft-tissue swellingComputed tomography scanConcomitant injuriesBilateral injuryRadiological findingsImaging findingsStudy cohortSubdural hematomaUnique patientsInjury patternsMean ageCommon manifestationHead injuryInjury typePrior injuryFeasibility and Safety of Exclusive Noncontrast Computed Tomography for Planning of Transcatheter Aortic Valve Implantation With Self-Expandable Valves
Hibino M, Yoon S, Dallan L, Pelletier M, Rushing G, Filby S, Elgudin Y, Ukaigwe A, Baeza C, Attizzani G. Feasibility and Safety of Exclusive Noncontrast Computed Tomography for Planning of Transcatheter Aortic Valve Implantation With Self-Expandable Valves. The American Journal Of Cardiology 2023, 190: 122-124. PMID: 36623398, DOI: 10.1016/j.amjcard.2022.12.018.Peer-Reviewed Original Research
2021
Mitochondria–cytoskeleton interactions in mammalian sperm revealed by cryoelectron tomography
Wang H, Chung JJ. Mitochondria–cytoskeleton interactions in mammalian sperm revealed by cryoelectron tomography. Proceedings Of The National Academy Of Sciences Of The United States Of America 2021, 118: e2118020118. PMID: 34819381, PMCID: PMC8640839, DOI: 10.1073/pnas.2118020118.Commentaries, Editorials and LettersAre cardiology fellows receiving enough basic level I cardiovascular computed tomography education during their general fellowship training? Insights from a needs assessment survey at an academic medical center
Hur DJ, Meadows JL, Baldassarre LA, Mojibian HR, Villines TC, Windish DM. Are cardiology fellows receiving enough basic level I cardiovascular computed tomography education during their general fellowship training? Insights from a needs assessment survey at an academic medical center. Journal Of Cardiovascular Computed Tomography 2021, 16: 186-188. PMID: 34600865, DOI: 10.1016/j.jcct.2021.09.005.Peer-Reviewed Original ResearchTranscatheter Aortic Valve Implant Depth Measurements Differ by Aortography Versus Computed Tomography
Vora A, Tang G, Reardon M, Deeb G, Yakubov S, Huang J, Spencer J, Gada H. Transcatheter Aortic Valve Implant Depth Measurements Differ by Aortography Versus Computed Tomography. JACC Cardiovascular Interventions 2021, 14: 1045-1047. PMID: 33744214, DOI: 10.1016/j.jcin.2020.12.035.Peer-Reviewed Original ResearchComputer vision applied to dual-energy computed tomography images for precise calcinosis cutis quantification in patients with systemic sclerosis
Chandrasekaran AC, Fu Z, Kraniski R, Wilson FP, Teaw S, Cheng M, Wang A, Ren S, Omar IM, Hinchcliff ME. Computer vision applied to dual-energy computed tomography images for precise calcinosis cutis quantification in patients with systemic sclerosis. Arthritis Research & Therapy 2021, 23: 6. PMID: 33407814, PMCID: PMC7788847, DOI: 10.1186/s13075-020-02392-9.Peer-Reviewed Original ResearchConceptsSSc patientsCalcinosis cutisCC lesionsSystemic sclerosisBland-Altman plotsConcordance correlation coefficientIndependent radiologistsLin's concordance correlation coefficientConfidence intervalsValid clinical trialsExpert musculoskeletal radiologistsSpearman correlation coefficientClinical trialsMusculoskeletal radiologistsPatientsBurden quantificationLesionsMean differenceGold standardRadiologistsCorrelation coefficientLonger lengthPhalanxSpearman's rhoValidation study
2020
Planning for the Next Transcatheter Aortic Valve Replacement Starts Today
Cavender M, Forrest J. Planning for the Next Transcatheter Aortic Valve Replacement Starts Today. Circulation Cardiovascular Interventions 2020, 13: e010226. PMID: 33272033, DOI: 10.1161/circinterventions.120.010226.Peer-Reviewed Original Research
2019
Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning
Meyer S, Kamp F, Tessonnier T, Mairani A, Belka C, Carlson DJ, Gianoli C, Parodi K. Dosimetric accuracy and radiobiological implications of ion computed tomography for proton therapy treatment planning. Physics In Medicine And Biology 2019, 64: 125008. PMID: 30870831, DOI: 10.1088/1361-6560/ab0fdf.Peer-Reviewed Original ResearchConceptsX-ray CTCalculation accuracyRSP accuracyDosimetric accuracyFLUKA Monte Carlo simulationsPotential replacementFixation modelProton therapy treatment planningProton CTModel predictionsIon therapy treatmentsConventional X-ray CTHeliumHigh accuracyBetter performanceCommon uncertaintyTracking detectorMonte Carlo simulationsAccuracyImaging doseSoft tissue
2018
Optoacoustics delineates murine breast cancer models displaying angiogenesis and vascular mimicry
Quiros-Gonzalez I, Tomaszewski M, Aitken S, Ansel-Bollepalli L, McDuffus L, Gill M, Hacker L, Brunker J, Bohndiek S. Optoacoustics delineates murine breast cancer models displaying angiogenesis and vascular mimicry. British Journal Of Cancer 2018, 118: 1098-1106. PMID: 29576623, PMCID: PMC5931091, DOI: 10.1038/s41416-018-0033-x.Peer-Reviewed Original ResearchMeSH KeywordsAnimalsBiological MimicryBreast NeoplasmsCell Line, TumorDrug MonitoringFemaleHumansMammary Neoplasms, ExperimentalMCF-7 CellsMiceMice, Inbred BALB CMice, NudeNeoplasm StagingNeovascularization, PathologicOxygen ConsumptionPhotoacoustic TechniquesSensitivity and SpecificityTomographyTumor HypoxiaXenograft Model Antitumor AssaysConceptsMDA-MB-231Breast cancer modelCancer modelsVascular mimicryOrthotopic breast cancer xenograftsVascular phenotypeMurine breast cancer modelMDA-MB-231 tumorsMCF-7Consistent with angiogenesisMCF-7 tumorsTotal hemoglobinBreast cancer xenograftsBreast tumor modelEx vivo analysisNO serum levelsTumor oxygenationEstrogen-independentCancer xenograftsSerum levelsEstrogen-dependentTherapeutic responseBreast tumorsTumor modelClinical trials
2015
Dimeric Organization of Blood Coagulation Factor VIII bound to Lipid Nanotubes
Dalm D, Galaz-Montoya J, Miller J, Grushin K, Villalobos A, Koyfman A, Schmid M, Stoilova-McPhie S. Dimeric Organization of Blood Coagulation Factor VIII bound to Lipid Nanotubes. Scientific Reports 2015, 5: 11212. PMID: 26082135, PMCID: PMC4469981, DOI: 10.1038/srep11212.Peer-Reviewed Original ResearchConceptsMembrane-bound factor VIIIMembrane-binding domainCryo-electron microscopyMembrane-bound structuresSerine protease factor IXaDeficiency of FVIIIDimeric organizationSubtomogram averagingComplex assemblyHelical reconstructionLipid nanotubesCritical functionsFactor IXaBlood coagulationBlood coagulation factor VIIIStructural informationCrystal structureCritical stepPlatelet membranesPlatelet surfaceSevere bleeding disorderCoagulation factor VIIIIntermediate resolutionBleeding disorderMembrane
2013
Studying synapses in human brain with array tomography and electron microscopy
Kay KR, Smith C, Wright AK, Serrano-Pozo A, Pooler AM, Koffie R, Bastin ME, Bak TH, Abrahams S, Kopeikina KJ, McGuone D, Frosch MP, Gillingwater TH, Hyman BT, Spires-Jones TL. Studying synapses in human brain with array tomography and electron microscopy. Nature Protocols 2013, 8: 1366-1380. PMID: 23787894, PMCID: PMC3712649, DOI: 10.1038/nprot.2013.078.Peer-Reviewed Original ResearchConceptsHuman brainClinicopathological correlationArray tomographySynapse densityPostmortem studiesPsychiatric illnessClinical cohortAutopsy tissueBrain bankingThousands of synapsesNeurodegenerative diseasesSynapsesUltrastructural studySerial sectionsSynapse levelHuman samplesDiseaseBrainDevelopmental diseasesTomographyLight microscopyUltrathin serial sectionsCohortIllnessPotent way
2010
Refraction corrected transmission ultrasound computed tomography for application in breast imaging
Li S, Jackowski M, Dione DP, Varslot T, Staib LH, Mueller K. Refraction corrected transmission ultrasound computed tomography for application in breast imaging. Medical Physics 2010, 37: 2233-2246. PMID: 20527557, PMCID: PMC2874040, DOI: 10.1118/1.3360180.Peer-Reviewed Original Research
2008
Tomographic subvolume alignment and subvolume classification applied to myosin V and SIV envelope spikes
Winkler H, Zhu P, Liu J, Ye F, Roux KH, Taylor KA. Tomographic subvolume alignment and subvolume classification applied to myosin V and SIV envelope spikes. Journal Of Structural Biology 2008, 165: 64-77. PMID: 19032983, PMCID: PMC2656979, DOI: 10.1016/j.jsb.2008.10.004.Peer-Reviewed Original ResearchThe role of filament-packing dynamics in powering amoeboid cell motility
Miao L, Vanderlinde O, Liu J, Grant RP, Wouterse A, Shimabukuro K, Philipse A, Stewart M, Roberts TM. The role of filament-packing dynamics in powering amoeboid cell motility. Proceedings Of The National Academy Of Sciences Of The United States Of America 2008, 105: 5390-5395. PMID: 18385381, PMCID: PMC2291107, DOI: 10.1073/pnas.0708416105.Peer-Reviewed Original ResearchClassification and 3D averaging with missing wedge correction in biological electron tomography
Bartesaghi A, Sprechmann P, Liu J, Randall G, Sapiro G, Subramaniam S. Classification and 3D averaging with missing wedge correction in biological electron tomography. Journal Of Structural Biology 2008, 162: 436-450. PMID: 18440828, PMCID: PMC2556382, DOI: 10.1016/j.jsb.2008.02.008.Peer-Reviewed Original ResearchConceptsMissing wedgeElectron tomographyReciprocal spacePhantom volumeAveraging of informationSingle-particle electron microscopyStructures of biological macromoleculesElectron crystallographyElectronMultiple copiesClassification operationsTomographic approachNumerous macromoleculesWhole cellsAlignment problemWedge correctionClassificationBiological macromoleculesAngular searchIntegrin αIIbβ3 in a Membrane Environment Remains the Same Height after Mn2+ Activation when Observed by Cryoelectron Tomography
Ye F, Liu J, Winkler H, Taylor KA. Integrin αIIbβ3 in a Membrane Environment Remains the Same Height after Mn2+ Activation when Observed by Cryoelectron Tomography. Journal Of Molecular Biology 2008, 378: 976-986. PMID: 18405917, PMCID: PMC2614134, DOI: 10.1016/j.jmb.2008.03.014.Peer-Reviewed Original Research
2006
Electron Tomography of Swollen Rigor Fibers of Insect Flight Muscle Reveals a Short and Variably Angled S2 Domain
Liu J, Wu S, Reedy MC, Winkler H, Lucaveche C, Cheng Y, Reedy MK, Taylor KA. Electron Tomography of Swollen Rigor Fibers of Insect Flight Muscle Reveals a Short and Variably Angled S2 Domain. Journal Of Molecular Biology 2006, 362: 844-860. PMID: 16949613, DOI: 10.1016/j.jmb.2006.07.084.Peer-Reviewed Original Research
2004
Electron tomography of fast frozen, stretched rigor fibers reveals elastic distortions in the myosin crossbridges
Liu J, Reedy M, Goldman Y, Franzini-Armstrong C, Sasaki H, Tregear R, Lucaveche C, Winkler H, Baumann B, Squire J, Irving T, Reedy M, Taylor K. Electron tomography of fast frozen, stretched rigor fibers reveals elastic distortions in the myosin crossbridges. Journal Of Structural Biology 2004, 147: 268-282. PMID: 15450296, DOI: 10.1016/j.jsb.2004.03.008.Peer-Reviewed Original Research
2003
Simultaneous optical coherence tomography imaging and beta particle detection.
Zhu Q, Piao D, Sadeghi MM, Sinusas AJ. Simultaneous optical coherence tomography imaging and beta particle detection. Optics Letters 2003, 28: 1704-6. PMID: 13677543, DOI: 10.1364/ol.28.001704.Peer-Reviewed Original ResearchMeSH KeywordsBeta ParticlesCatheterizationFeasibility StudiesHumansOptics and PhotonicsTomographyVascular Diseases
1982
Tomographic gallium-67 citrate scanning: useful new surveillance for metastatic melanoma.
KIRKWOOD J, MYERS J, VLOCK D, NEUMANN R, ARIYAN S, GOTTSCHALK A, HOFFER P. Tomographic gallium-67 citrate scanning: useful new surveillance for metastatic melanoma. Annals Of Internal Medicine 1982, 97: 694-9. PMID: 7137734, DOI: 10.7326/0003-4819-97-5-694.Peer-Reviewed Original ResearchConceptsLymph nodesMetastatic melanomaTomographic scanBone sitesEvident lymph nodesIndependent clinical evaluationProspective surveillance studyPeripheral lymph nodesSoft tissue sitesLymphatic sitesMediastinal sitesGallium scanGallium imagingPulmonary sitesClinical evaluationTomographic scanningAbdominal sitesGallium uptakeBrain sitesOsseous sitesSurveillance studyDiscordant findingsTissue sitesOverall sensitivityMelanoma
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply