2024
Comparing the Accuracy and Reliability of ABC/2 and Planimetry for Vestibular Schwannoma Volume Assessment
Singh K, Abdou H, Panth N, Chiang V, Buono F, Schwartz N, Mahajan A. Comparing the Accuracy and Reliability of ABC/2 and Planimetry for Vestibular Schwannoma Volume Assessment. Otology & Neurotology 2024, 46: 196-200. PMID: 39792983, DOI: 10.1097/mao.0000000000004392.Peer-Reviewed Original ResearchConceptsTumor volume assessmentABC/2 methodVestibular schwannomaVolume assessmentPlanimetry methodTumor volumeTumor volume changesFollow-up scansOverestimate tumor volumePatients' quality of lifeTumor sizeRetrospective reviewIntracranial tumorsImprove clinical decision makingSubgroup analysisVolumetric assessmentTumorClinical decision makingQuality of lifePatients' qualityPatientsClinical settingPlanimetryImaging techniquesPositive correlationNoninvasive Gamma Sensory Stimulation May Reduce White Matter and Myelin Loss in Alzheimer’s Disease
Da X, Hempel E, Ou Y, Rowe O, Malchano Z, Hajós M, Kern R, Megerian J, Cimenser A. Noninvasive Gamma Sensory Stimulation May Reduce White Matter and Myelin Loss in Alzheimer’s Disease. Journal Of Alzheimer's Disease 2024, 97: 359-372. PMID: 38073386, PMCID: PMC10789351, DOI: 10.3233/jad-230506.Peer-Reviewed Original ResearchConceptsWhite matter atrophyActive treatment participantsMatter atrophyAlzheimer's diseaseMyelin lossTreatment participantsWhite matterNeuronal network functionT2-weighted MRIEarly disease interventionMRI outcomesClinical trialsEntorhinal regionWhite matter structuresHz stimulationMagnetic resonance imaging dataAfferent connectionsInclusion criteriaTherapeutic approachesAtrophySensory stimulationVolume assessmentDisease interventionDiseaseMyelin content
2023
Perioperative Fluid Management and Volume Assessment
Elia J, Diwan M, Deshpande R, Brainard J, Karamchandani K. Perioperative Fluid Management and Volume Assessment. Anesthesiology Clinics 2023, 41: 191-209. PMID: 36871999, DOI: 10.1016/j.anclin.2022.10.010.Peer-Reviewed Original ResearchConceptsPerioperative fluid managementFluid managementFluid responsivenessFluid therapyAdequate organ perfusionIntraoperative fluid managementEvidence-based recommendationsCardiac preloadPerioperative careVolume statusVolume responsivenessStroke volumeOrgan perfusionBlood volumeVolume assessmentTherapyResponsivenessAccurate assessmentManagement
2022
Inferior Vena Cava Diameter Measurement Provides Distinct and Complementary Information to Right Atrial Pressure in Acute Decompensated Heart Failure
Griffin M, Ivey-Miranda J, McCallum W, Sarnak M, Eder M, Bellumkonda L, Maulion C, Wilson FP, Rao VS, Testani J. Inferior Vena Cava Diameter Measurement Provides Distinct and Complementary Information to Right Atrial Pressure in Acute Decompensated Heart Failure. Journal Of Cardiac Failure 2022, 28: 1217-1221. PMID: 35301109, DOI: 10.1016/j.cardfail.2022.02.014.Peer-Reviewed Original ResearchConceptsRight atrial pressureAcute decompensated heart failureDecompensated heart failureIVC diameterAtrial pressureHeart failureInferior vena cava diameter (IVCD) measurementBaseline right atrial pressureInferior vena cava (IVC) measurementsPulmonary artery catheterVena cava diameter measurementsArtery catheterHemoglobin levelsIntravascular volumeVenous systemESCAPE trialIVC measurementsBlood volumeRAP measurementsSurvival ratePatientsVolume assessmentHigh complianceModest correlationMedian
2020
Non-invasive venous waveform analysis (NIVA) for volume assessment in patients undergoing hemodialysis: an observational study
Alvis BD, Polcz M, Miles M, Wright D, Shwetar M, Leisy P, Forbes R, Fissell R, Whitfield J, Eagle S, Brophy C, Hocking K. Non-invasive venous waveform analysis (NIVA) for volume assessment in patients undergoing hemodialysis: an observational study. BMC Nephrology 2020, 21: 194. PMID: 32448178, PMCID: PMC7245891, DOI: 10.1186/s12882-020-01845-2.Peer-Reviewed Original ResearchConceptsNon-Invasive Venous waveform AnalysisIntradialytic hypotensionNIVA valueVolume statusPre-dialysis levelsIntravascular volume statusEnd of dialysisInpatient hemodialysisIntradialytic changesMethodsFifty subjectsInadequate dialysisConcept studyVolar aspectBackgroundAccurate assessmentAccess siteObservational studyClinical challengeCardiac rateSmall cohortNon-invasive techniqueWaveform analysisHemodialysisPatientsVolume assessmentDialysis
2017
Validation of a defibrillation lead ventricular volume measurement compared to three-dimensional echocardiography
Haines D, Wong W, Canby R, Jewell C, Houmsse M, Pederson D, Sugeng L, Porterfield J, Kottam A, Pearce J, Valvano J, Michalek J, Trevino A, Sagar S, Feldman M. Validation of a defibrillation lead ventricular volume measurement compared to three-dimensional echocardiography. Heart Rhythm 2017, 14: 1515-1522. PMID: 28603000, DOI: 10.1016/j.hrthm.2017.06.005.Peer-Reviewed Original ResearchConceptsStroke volumeOverdrive pacingImplantable defibrillatorsMonitor cardiac hemodynamicsThree-dimensional echocardiographyEnd-diastolic volumeVentricular volume assessmentCardiac hemodynamicsHeart failureInvasive measures of pressureHemodynamic challengesDefibrillation leadVolume assessmentImprove outcomesPatientsDefibrillationEchocardiographyMeasurements of volumeVVSHemodynamicsGenerator replacementHeartMeasurements of pressure
2012
Quantitative and Volumetric European Association for the Study of the Liver and Response Evaluation Criteria in Solid Tumors Measurements: Feasibility of a Semiautomated Software Method to Assess Tumor Response after Transcatheter Arterial Chemoembolization
Lin M, Pellerin O, Bhagat N, Rao P, Loffroy R, Ardon R, Mory B, Reyes D, Geschwind J. Quantitative and Volumetric European Association for the Study of the Liver and Response Evaluation Criteria in Solid Tumors Measurements: Feasibility of a Semiautomated Software Method to Assess Tumor Response after Transcatheter Arterial Chemoembolization. Journal Of Vascular And Interventional Radiology 2012, 23: 1629-1637. PMID: 23177109, PMCID: PMC3579576, DOI: 10.1016/j.jvir.2012.08.028.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedAged, 80 and overAntineoplastic AgentsCarcinoma, HepatocellularChemoembolization, TherapeuticFemaleHumansImaging, Three-DimensionalLiver NeoplasmsMagnetic Resonance ImagingMaleMiddle AgedPattern Recognition, AutomatedReproducibility of ResultsSensitivity and SpecificitySoftwareSoftware ValidationTreatment OutcomeTumor BurdenConceptsTranscatheter arterial chemoembolizationArterial chemoembolizationHepatocellular carcinomaDrug-eluting bead transcatheter arterial chemoembolizationSingle-institution prospective studyResponse Evaluation CriteriaContrast-enhanced magnetic resonanceHepatic tumor volumeSolid tumor measurementsThree-dimensional volumetric assessmentMagnetic resonanceIntraarterial therapyProspective studyTumor responseClinical correlationTumor measurementsTumor volumeTumor enhancementInterventional radiologistsPatientsVolumetric assessmentChemoembolizationEuropean AssociationVolume assessmentVoxel basis
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply