2024
Elevated myocardial extracellular volume fraction is associated with the development of conduction pathway defects following transcatheter aortic valve replacement
Feroze R, Kang P, Dallan L, Akula N, Galo J, Yoon S, Ukaigwe A, Filby S, Baeza C, Pelletier M, Rushing G, Rajagopalan S, Al‐Kindi S, Rashid I, Attizzani G. Elevated myocardial extracellular volume fraction is associated with the development of conduction pathway defects following transcatheter aortic valve replacement. Catheterization And Cardiovascular Interventions 2024, 104: 1119-1128. PMID: 38952304, DOI: 10.1002/ccd.31136.Peer-Reviewed Original ResearchMeSH KeywordsAction PotentialsAgedAged, 80 and overAortic ValveAortic Valve StenosisArea Under CurveAtrioventricular BlockBundle-Branch BlockCardiac Pacing, ArtificialFemaleFibrosisHeart Conduction SystemHumansMagnetic Resonance Imaging, CineMaleMyocardiumPacemaker, ArtificialPredictive Value of TestsRetrospective StudiesRisk AssessmentRisk FactorsROC CurveTime FactorsTranscatheter Aortic Valve ReplacementTreatment OutcomeConceptsTranscatheter aortic valve replacementCardiac magnetic resonance imagingLate gadolinium enhancementRight bundle branch blockArea under the receiver operating characteristic curveAortic valve replacementReceiver operating curveMyocardial fibrosisPost-TAVRConduction defectsBundle branch blockAssociations of myocardial fibrosisExtracellular volumeConduction diseaseValve replacementGadolinium enhancementPermanent pacemakerConduction abnormalitiesConduction deficitsHeart blockBranch blockRisk of heart blockSeptal late gadolinium enhancementMyocardial extracellular volume fractionBaseline conduction disease
2023
Clinical impact of right ventricular pacing burden in patients with post-transcatheter aortic valve replacement permanent pacemaker implantation
Tsushima T, Al-Kindi S, Dallan L, Fares A, Yoon S, Wheat H, Attizzani G, Baeza C, Pelletier M, Arruda M, Mackall J, Thal S. Clinical impact of right ventricular pacing burden in patients with post-transcatheter aortic valve replacement permanent pacemaker implantation. EP Europace 2023, 25: 1441-1450. PMID: 36794441, PMCID: PMC10105841, DOI: 10.1093/europace/euad025.Peer-Reviewed Original ResearchConceptsRight ventricular pacing burdenTranscatheter aortic valve replacementVentricular pacing burdenPermanent pacemaker implantationPermanent pacemakerHeart failurePacing burdenPPM implantationRetrospective study of consecutive patientsLikelihood of heart failureStudy of consecutive patientsLeft ventricular ejection fractionAssociated with worse outcomesVentricular ejection fractionAortic valve replacementAtrial fibrillation burdenValve implantation depthConsecutive patientsEjection fractionValve replacementPost-TAVRClinical benefitPacemaker implantationRetrospective studySingle-centre
2018
Clinical Significance of Greater Implantation Height with SAPIEN 3 Transcatheter Heart Valve.
Ramirez Del Val F, Hirji S, Carreras E, Kolkailah A, Chowdhury R, McGurk S, Lee J, Nyman C, Shook D, Sobieszczyk P, Pelletier M, Shah P, Kaneko T. Clinical Significance of Greater Implantation Height with SAPIEN 3 Transcatheter Heart Valve. The Journal Of Heart Valve Disease 2018, 27: 9-16. PMID: 30560594.Peer-Reviewed Original ResearchConceptsTranscatheter aortic valve replacementRight bundle branch blockPreoperative right bundle branch blockPermanent pacemaker implantationRate of PPM implantationSAPIEN 3 valvePermanent pacemakerPPM implantationOperative mortalityHigher implantationHI patientsSociety of Thoracic Surgeons Predicted RiskClinical significanceAssociated with PPM implantationImplant heightTranscatheter aortic valve replacement patientsThoracic Surgeons Predicted RiskRates of permanent pacemakerStandard implantsIncreased operative mortalityAortic valve replacementLong-term followTranscatheter heart valveBundle branch blockValve replacement
2016
Transapical Cannulation Through a Transcatheter Aortic Valve Implantation Valve: A Novel Approach for Cardiogenic Collapse
Tremblay L, Cote C, Pelletier M. Transapical Cannulation Through a Transcatheter Aortic Valve Implantation Valve: A Novel Approach for Cardiogenic Collapse. Seminars In Thoracic And Cardiovascular Surgery 2016, 28: 400-402. PMID: 28043451, DOI: 10.1053/j.semtcvs.2016.05.012.Peer-Reviewed Original ResearchMeSH KeywordsAgedAortic ValveAortic Valve StenosisBalloon ValvuloplastyCardiac CatheterizationCardiac Pacing, ArtificialCardiopulmonary BypassHeart Valve Prosthesis ImplantationHumansMalePeripheral Vascular DiseasesRadiography, InterventionalRecovery of FunctionSeverity of Illness IndexShockTreatment OutcomeVascular CalcificationConceptsCardiopulmonary bypassVentricular apexInitiation of cardiopulmonary bypassTranscatheter aortic valve implantation proceduresTranscatheter aortic-valve implantation valveLeft ventricular apexPatients' ventricular functionValve implantation proceduresPeripheral cannulationVentricular functionTranscatheter valvesCardiac functionProsthetic valvesImplanted valveImplantation procedureTransapical cannulationArterial cannulaCannulationTranscatheterPatientsBypass
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply