2025
Flexible and modular PET: Evaluating the potential of TOF‐DOI panel detectors
Razdevšek G, Fakhri G, Marin T, Dolenec R, Orehar M, Chemli Y, Gola A, Gascon D, Majewski S, Pestotnik R. Flexible and modular PET: Evaluating the potential of TOF‐DOI panel detectors. Medical Physics 2025, 52: 2845-2860. PMID: 40089973, PMCID: PMC12059530, DOI: 10.1002/mp.17741.Peer-Reviewed Original ResearchDepth of interactionLong axial field-of-viewTime-of-flightPanel detectorHigh-performance computing clusterDepth-of-interaction resolutionNoise equivalent count rateDepth-of-interaction capabilityDepth-of-interaction detectorsAxial field-of-viewImage qualityTime-of-Flight (TOFDistortion-free imagesPositron emission tomography scannerLong axial fieldComputer clusterSpatial resolutionLSO crystalsImage reconstructionDetector materialCount rateGATE softwareContrast-to-noise ratioParallax errorMonte Carlo simulations
2024
Flat Panel TOF-PET Detectors: a Simulation Study
Orehar M, Dolenec R, Fakhri G, Gascón D, Gola A, Korpar S, Križan P, Razdevšek G, Marin T, Chemli Y, Žontar D, Pestotnik R. Flat Panel TOF-PET Detectors: a Simulation Study. 2024, 00: 1-2. DOI: 10.1109/nss/mic/rtsd57108.2024.10658250.Peer-Reviewed Original ResearchTime resolutionAngular coverageFlat-panel detectorScintillation materialsGATE softwareAxial coverageBiograph VisionPanel detectorTotal-body coverageClinical scannerImage reconstructionDetectorReconstructed imagesHomogeneous contrastCylindrical scannerImage qualityState-of-the-artScintillationHigh-performance computingScannerPhantomResolutionCore hoursPositron emission tomographyGate
2022
Optimization of Design Parameters of Flat Panel Limited Angle TOF-PET Scanner: a Simulation Study
Orehar M, Dolenec R, Fakhri G, Gascón D, Gola A, Korpar S, Križan P, Razdevšek G, Pestotnik R. Optimization of Design Parameters of Flat Panel Limited Angle TOF-PET Scanner: a Simulation Study. 2022, 00: 1-4. DOI: 10.1109/nss/mic44845.2022.10399330.Peer-Reviewed Original ResearchImage quality phantomFlat-panel detectorGATE softwareRing scannerPanel detectorDetection chainState-of-the-artNEMA standardsOpen geometryImage reconstructionReconstructed imagesPositron emission tomographyState-of-the-art scannersScannerPhantomDetectorPhotodetectorsElectronNEMAMaterial costGatePositron
This site is protected by hCaptcha and its Privacy Policy and Terms of Service apply