1998
Efficacy of Coronary Stenting Versus Balloon Angioplasty in Small Coronary Arteries fn1fn1This study was supported in part by a grant from Johnson & Johnson Interventional Systems, Inc., Warren, New Jersey.
Savage M, Fischman D, Rake R, Leon M, Schatz R, Penn I, Nobuyoshi M, Moses J, Hirshfeld J, Heuser R, Baim D, Cleman M, Brinker J, Gebhardt S, Goldberg S, Investigators F. Efficacy of Coronary Stenting Versus Balloon Angioplasty in Small Coronary Arteries fn1fn1This study was supported in part by a grant from Johnson & Johnson Interventional Systems, Inc., Warren, New Jersey. Journal Of The American College Of Cardiology 1998, 31: 307-311. PMID: 9462572, DOI: 10.1016/s0735-1097(97)00511-1.Peer-Reviewed Original ResearchMeSH KeywordsAngioplasty, Balloon, CoronaryChi-Square DistributionCohort StudiesCoronary AngiographyCoronary DiseaseCoronary VesselsDisease-Free SurvivalElective Surgical ProceduresEquipment DesignFemaleFollow-Up StudiesHumansLinear ModelsMaleMiddle AgedRecurrenceStentsSurvival RateTreatment OutcomeUnited StatesUnited States Food and Drug AdministrationConceptsElective stent placementBalloon angioplastyCoronary arteryStent placementElective stent implantationJohnson Interventional SystemsPostprocedural lumen diameterPrimary end pointEvent-free survivalClinical event ratesSmall coronary arteriesQuantitative coronary angiographyPalmaz-Schatz stentsAngioplasty groupAngiographic characteristicsCoronary angiographyClinical outcomesNew lesionsProcedural successDiameter stenosisStent groupStent implantationAbrupt closurePatientsAngioplasty
1995
1017-74 Length of Hospital Stay After Percutaneous Transluminal Coronary Angioplasty: Clinical and Angiographic Predictors
Bittl J, Wolfe M, Roubin G, Schweiger M, Isner J, Ferguson J, Cannon A, Cleman M, Cabin H, Leya F, Bonan R, Strony J, Adelman B, Investigators H. 1017-74 Length of Hospital Stay After Percutaneous Transluminal Coronary Angioplasty: Clinical and Angiographic Predictors. Journal Of The American College Of Cardiology 1995, 25: 392a. DOI: 10.1016/0735-1097(95)93083-o.Peer-Reviewed Original Research
1994
Physiologic assessment of ostial left circumflex coronary artery disease using a doppler guidewire before and after rotational atherectomy facilitated angioplasty
Ling F, Brennan J, Cleman M, Cabin H. Physiologic assessment of ostial left circumflex coronary artery disease using a doppler guidewire before and after rotational atherectomy facilitated angioplasty. Catheterization And Cardiovascular Interventions 1994, 32: 53-57. PMID: 8039221, DOI: 10.1002/ccd.1810320113.Peer-Reviewed Case Reports and Technical NotesConceptsRotational atherectomyCircumflex coronary artery diseaseCoronary artery diseaseCoronary flow velocitySuccessful rotational atherectomyCoronary interventionArtery diseaseOstial stenosisDoppler assessmentDoppler evaluationPhysiologic assessmentDoppler guidewireIntermediate stenosisPhysiologic significanceFlow velocity characteristicsAngioplastyAtherectomyStenosisPatientsDiseaseGuidewirePredictors of Coronary Dissection following Percutaneous Transluminal Coronary Balloon Angioplasty
Ilia R, Bigham H, Brennan J, Cabin H, Cleman M, Remetz M. Predictors of Coronary Dissection following Percutaneous Transluminal Coronary Balloon Angioplasty. Cardiology 1994, 85: 229-234. PMID: 7987880, DOI: 10.1159/000176680.Peer-Reviewed Original ResearchConceptsCoronary dissectionLong lesionsPercutaneous transluminal coronary balloon angioplastyNon-Q-wave myocardial infarctionAcute coronary dissectionCoronary balloon angioplastyConsecutive patientsCoronary angioplastyBalloon dilatationFemale patientsArterial dilatationBalloon angioplastyMyocardial infarctionMost dissectionsPatientsMore dissectionAngioplastyDissectionLesionsComplicationsArteryDilatationPredictorsInfarctionWomen
1993
Fate of lesion-related side branches after coronary artery stenting
Fischman D, Savage M, Leon M, Schatz R, Ellis S, Cleman M, Hirshfeld J, Teirstein P, Bailey S, Walker C, Goldberg S. Fate of lesion-related side branches after coronary artery stenting. Journal Of The American College Of Cardiology 1993, 22: 1641-1646. PMID: 8227832, DOI: 10.1016/0735-1097(93)90589-s.Peer-Reviewed Original ResearchConceptsSide branch occlusionStandard balloon angioplastyBalloon angioplastyBranch occlusionOstial stenosisCoronary arteryStent placementAcute side branch occlusionPalmaz-Schatz stent placementSide branchesImportant potential complicationConventional balloon angioplastySerial coronary angiographyLong-term patencySide branch ostiumPossible adverse effectsConventional angioplastyCoronary angiographyCoronary stentingMechanical obstructionPotential complicationsOstial diseaseAngioplastyPatencyCoronary stentsMyocardial risk area defined by technetium-99m sestamibi imaging during percutaneous transluminal coronary angioplasty: Comparison with coronary angiography
Haronian H, Remetz M, Sinusas A, Baron J, Miller H, Cleman M, Zaret B, Wackers F. Myocardial risk area defined by technetium-99m sestamibi imaging during percutaneous transluminal coronary angioplasty: Comparison with coronary angiography. Journal Of The American College Of Cardiology 1993, 22: 1033-1043. PMID: 8409038, DOI: 10.1016/0735-1097(93)90413-u.Peer-Reviewed Original ResearchMeSH KeywordsAdultAgedAged, 80 and overAngioplasty, Balloon, CoronaryClinical ProtocolsCollateral CirculationCoronary AngiographyCoronary DiseaseEvaluation Studies as TopicFemaleHumansMaleMiddle AgedMyocardial InfarctionObserver VariationPredictive Value of TestsPrognosisReproducibility of ResultsRisk FactorsSeverity of Illness IndexTechnetium Tc 99m SestamibiTomography, Emission-Computed, Single-PhotonConceptsMyocardial risk areaCoronary angiographyCoronary angioplastyQuantitative myocardial perfusionMyocardial perfusionMyocardial areaPercutaneous transluminal coronary angioplastyAngiographic risk scoresSmall risk areasTransluminal coronary angioplastyCoronary artery diseaseCoronary artery stenosisInitial myocardial uptakeAngioplasty balloon inflationArtery diseaseLeft anteriorNonperfused areaArtery stenosisCoronary anatomyCoronary arteryBalloon inflationPatient managementMyocardial uptakeRisk scoreAngioplastyClinical and Angiographic Determinants of Initial Percutaneous Transluminal Coronary Angioplasty Success
Ilia R, Kolanski D, Setaro J, Brennan J, Cabin H, Cleman M, Remetz M. Clinical and Angiographic Determinants of Initial Percutaneous Transluminal Coronary Angioplasty Success. Angiology 1993, 44: 677-682. PMID: 8357092, DOI: 10.1177/000331979304400901.Peer-Reviewed Original ResearchConceptsCoronary angioplastyPercutaneous transluminal coronary angioplastyTransluminal coronary angioplastyAcute myocardial infarctionSuccess rateDegree of stenosisLong-term pretreatmentAngiographic determinantsAngioplasty successPostinfarction anginaAngiographic characteristicsSuccessful angioplastyClinical featuresMyocardial infarctionAnatomic determinantsPrimary successAngioplastyPatientsSuccessful procedureAspirinBeneficial effectsLesionsHigh rateAdditional findingsAnginaCoronary angioplasty with gradual versus rapid balloon inflation: Initial results and complications
Ilia R, Cabin H, McConnell S, Cleman M, Remetz M. Coronary angioplasty with gradual versus rapid balloon inflation: Initial results and complications. Catheterization And Cardiovascular Interventions 1993, 29: 199-202. PMID: 8402842, DOI: 10.1002/ccd.1810290305.Peer-Reviewed Original ResearchConceptsInflation protocolFrequency of dissectionLesion morphological characteristicsRapid balloon inflationProcedure-related complicationsComplete success rateSuccess rateGradual inflationUnstable anginaComplication rateCoronary angioplastySignificant group differencesArterial damageBalloon inflationDissection rateHigh success rateDiseased vesselsMore lesionsPatientsLesionsInflation groupGroup differencesAngioplastyComplicationsVessel diameter ratio
1992
Characteristics of cigarette smokers versus nonsmokers in patients referred for coronary angioplasty
Ilia R, Brennan J, Cabin H, Cleman M, Remetz M. Characteristics of cigarette smokers versus nonsmokers in patients referred for coronary angioplasty. Coronary Artery Disease 1992, 3: 859-862. DOI: 10.1097/00019501-199209000-00013.Peer-Reviewed Original ResearchPercutaneous transluminal coronary angioplastyTransluminal coronary angioplastyCoronary angioplastyCoronary dissectionSuccess rateConsecutive patientsMajor complicationsCigarette smokersTotal occlusionLong lesionsAngioplastySmokersConsecutive lesionsPatientsLesionsNonsmokersDissectionComplicationsGroupOcclusion
1991
Effect of intracoronary stenting on intimal dissection after balloon angioplasty: Results of quantitative and qualitative coronary analysis
Fischman D, Savage M, Leon M, Schatz R, Ellis S, Cleman M, Teirstein P, Walker C, Bailey S, Hirshfeld J, Goldberg S. Effect of intracoronary stenting on intimal dissection after balloon angioplasty: Results of quantitative and qualitative coronary analysis. Journal Of The American College Of Cardiology 1991, 18: 1445-1451. PMID: 1939944, DOI: 10.1016/0735-1097(91)90673-w.Peer-Reviewed Original ResearchConceptsResidual luminal stenosisIntimal dissectionBalloon angioplastyIntracoronary stentingAngiographic appearanceStent implantationLuminal stenosisGrade 0Simple dissectionMean diameter stenosisComplex dissectionConventional balloon angioplastyPalmaz-Schatz stentsQuantitative coronary analysisConventional angioplastyConsecutive patientsCoronary angiographyIntimal disruptionDiameter stenosisDissection gradeAngioplastyGrade 2Grade 1StenosisDissection
1990
Metabolic and functional effects of perfluorocarbon distal perfusion during coronary angioplasty
Young L, Jaffe C, Revkin J, McNulty P, Cleman M. Metabolic and functional effects of perfluorocarbon distal perfusion during coronary angioplasty. The American Journal Of Cardiology 1990, 65: 986-990. PMID: 2327360, DOI: 10.1016/0002-9149(90)91001-m.Peer-Reviewed Original ResearchConceptsGreat cardiac veinDistal perfusionLactate releaseEjection fractionVentricular functionCardiac veinBalloon inflationLeft ventricular ejection fractionDistal coronary perfusionMyocardial lactate metabolismVentricular ejection fractionMyocardial lactate releaseRegional contractile functionNet lactate extractionNet lactate releaseCoronary angioplastyLeft anteriorCoronary perfusionLactate extractionContractile functionPerfusionAngioplastyLactate concentrationLactate metabolismOxygenated perfluorocarbonEffect of intracoronary stenting on intimal dissection following balloon angioplasty: Results of qualitative and quantitative coronary analysis
Fischman D, Savage M, Leon M, Hirshfeld J, Cleman M, Ellis S, Schatz R, Goldberg S. Effect of intracoronary stenting on intimal dissection following balloon angioplasty: Results of qualitative and quantitative coronary analysis. Journal Of The American College Of Cardiology 1990, 15: a119. DOI: 10.1016/0735-1097(90)92191-4.Peer-Reviewed Original Research
1988
Myocardial Protection During Percutaneous Transluminal Coronary Angioplasty
Lasala J, Cleman M. Myocardial Protection During Percutaneous Transluminal Coronary Angioplasty. Cardiology Clinics 1988, 6: 329-343. PMID: 2977571, DOI: 10.1016/s0733-8651(18)30481-8.Peer-Reviewed Original ResearchUpdate on Percutaneous Transluminal Coronary Angioplasty
Cabin H, Cleman M. Update on Percutaneous Transluminal Coronary Angioplasty. Cardiology Clinics 1988, 6: 321-328. PMID: 2977570, DOI: 10.1016/s0733-8651(18)30480-6.Peer-Reviewed Original Research