2023
Comprehensive Multimodality Imaging of Congenitally Corrected Transposition of the Great Arteries Incidentally Found to Have Coronary Ischemia
Sasse A, Feher A, Thorn S, Fahey J, Keeshan B, Sinusas A, Mojibian H, Steele J. Comprehensive Multimodality Imaging of Congenitally Corrected Transposition of the Great Arteries Incidentally Found to Have Coronary Ischemia. Circulation Cardiovascular Imaging 2023, 16: 597-600. PMID: 37092334, DOI: 10.1161/circimaging.122.015158.Peer-Reviewed Case Reports and Technical NotesThe Association Between Obstructive Sleep Apnea and Abnormal 82Rubidium Cardiac PET Perfusion Myocardial Flow Reserve
Aneni E, Thorn S, Feher A, Hong Chen J, Sinusas A, Yaggi H, Miller E. The Association Between Obstructive Sleep Apnea and Abnormal 82Rubidium Cardiac PET Perfusion Myocardial Flow Reserve. JACC Cardiovascular Imaging 2023, 16: 856-858. PMID: 36881426, PMCID: PMC10718199, DOI: 10.1016/j.jcmg.2022.11.024.Peer-Reviewed Original ResearchCT attenuation correction improves quantitative risk prediction by cardiac SPECT in obese patients
Feher A, Pieszko K, Shanbhag A, Lemley M, Bednarski B, Miller R, Huang C, Miras L, Liu Y, Sinusas A, Slomka P, Miller E. CT attenuation correction improves quantitative risk prediction by cardiac SPECT in obese patients. European Journal Of Nuclear Medicine And Molecular Imaging 2023, 51: 695-706. PMID: 37924340, DOI: 10.1007/s00259-023-06484-x.Peer-Reviewed Original ResearchMajor adverse cardiac eventsMyocardial perfusion imagingSPECT myocardial perfusion imagingMACE-free survivalObese patientsPrognostic valueSignificant incremental prognostic valueYale-New Haven HospitalLate coronary revascularizationStress total perfusion deficitAdverse cardiac eventsIncremental prognostic valueNonfatal myocardial infarctionComposite end pointCT myocardial perfusion imagingSuperior prognostic valueSPECT/CT myocardial perfusion imagingTotal perfusion deficitNew Haven HospitalCT attenuation correctionHighest ROC areaStress TPDCoronary revascularizationCardiac eventsPatient populationComparison of the prognostic value between quantification and visual estimation of coronary calcification from attenuation CT in patients undergoing SPECT myocardial perfusion imaging
Feher A, Pieszko K, Shanbhag A, Lemley M, Miller R, Huang C, Miras L, Liu Y, Gerber J, Sinusas A, Miller E, Slomka P. Comparison of the prognostic value between quantification and visual estimation of coronary calcification from attenuation CT in patients undergoing SPECT myocardial perfusion imaging. The International Journal Of Cardiovascular Imaging 2023, 40: 185-193. PMID: 37845406, PMCID: PMC466934, DOI: 10.1007/s10554-023-02980-1.Peer-Reviewed Original ResearchConceptsMajor adverse cardiovascular eventsCoronary artery calcificationMyocardial perfusion imagingCT myocardial perfusion imagingSPECT/CT myocardial perfusion imagingArtery calcificationPrognostic valuePrior coronary stentingAdverse cardiovascular eventsSimilar prognostic valueSPECT myocardial perfusionREFINE SPECT registrySPECT/CTCardiovascular eventsCAC scoringCalcium scoreCoronary calcificationCoronary stentingPrognostic utilitySingle centerCoronary arteryLow doseMyocardial perfusionPerfusion imagingSurvival analysis99mTc/123I Dual-Radionuclide Correction for Self-Scatter, Down-Scatter, and Tailing Effect for a CZT SPECT With Varying Tracer Distributions
Velo A, Fan P, Xie H, Chen X, Boutagy N, Feher A, Sinusas A, Ljungberg M, Liu C. 99mTc/123I Dual-Radionuclide Correction for Self-Scatter, Down-Scatter, and Tailing Effect for a CZT SPECT With Varying Tracer Distributions. IEEE Transactions On Radiation And Plasma Medical Sciences 2023, 7: 839-850. PMID: 38745858, PMCID: PMC11090119, DOI: 10.1109/trpms.2023.3297443.Peer-Reviewed Original ResearchSegmentation-Free PVC for Cardiac SPECT Using a Densely-Connected Multi-Dimensional Dynamic Network
Xie H, Liu Z, Shi L, Greco K, Chen X, Zhou B, Feher A, Stendahl J, Boutagy N, Kyriakides T, Wang G, Sinusas A, Liu C. Segmentation-Free PVC for Cardiac SPECT Using a Densely-Connected Multi-Dimensional Dynamic Network. IEEE Transactions On Medical Imaging 2023, 42: 1325-1336. PMID: 36459599, PMCID: PMC10204821, DOI: 10.1109/tmi.2022.3226604.Peer-Reviewed Original ResearchCorrection to: Integration of coronary artery calcium scoring from CT attenuation scans by machine learning improves prediction of adverse cardiovascular events in patients undergoing SPECT/CT myocardial perfusion imaging
Feher A, Pieszko K, Miller R, Lemley M, Shanbhag A, Huang C, Miras L, Liu Y, Sinusas A, Miller E, Slomka P. Correction to: Integration of coronary artery calcium scoring from CT attenuation scans by machine learning improves prediction of adverse cardiovascular events in patients undergoing SPECT/CT myocardial perfusion imaging. Journal Of Nuclear Cardiology 2023, 30: 860-863. PMID: 36598750, DOI: 10.1007/s12350-022-03196-x.Peer-Reviewed Original ResearchImpaired left-ventricular global longitudinal strain by feature-tracking cardiac MRI predicts mortality in systemic sclerosis
Feher A, Miller E, Peters D, Mojibian H, Sinusas A, Hinchcliff M, Baldassarre L. Impaired left-ventricular global longitudinal strain by feature-tracking cardiac MRI predicts mortality in systemic sclerosis. Rheumatology International 2023, 43: 849-858. PMID: 36894756, DOI: 10.1007/s00296-023-05294-6.Peer-Reviewed Original ResearchConceptsLate gadolinium enhancementLV-GLSSystemic sclerosisWorse survivalClinical indicationsImpaired left ventricular global longitudinal strainLeft ventricular global longitudinal strainPresence of LGECMR strainLV cardiac indexWorse LV-GLSLV ejection fractionCox regression analysisGlobal longitudinal strainLV cardiac outputGlobal radialCardiac indexOverall survivalRetrospective cohortEjection fractionPrognostic valueAdverse outcomesCardiac outputGadolinium enhancementRV strainCORONARY ARTERY CALCIFICATIONS ARE A BETTER PREDICTOR OF CARDIOVASCULAR OUTCOMES THAN ISCHEMIC ECG CHANGES IN PATIENTS WITH NORMAL PERFUSION ON EXERCISE SPECT
Shi T, Kokkinidis D, Agarwal R, Liu Y, Sinusas A, Miller E, Feher A. CORONARY ARTERY CALCIFICATIONS ARE A BETTER PREDICTOR OF CARDIOVASCULAR OUTCOMES THAN ISCHEMIC ECG CHANGES IN PATIENTS WITH NORMAL PERFUSION ON EXERCISE SPECT. Journal Of The American College Of Cardiology 2023, 81: 1498. DOI: 10.1016/s0735-1097(23)01942-3.Peer-Reviewed Original ResearchIN PATIENTS UNDERGOING NUCLEAR MYOCARDIAL PERFUSION IMAGING, RHEUMATOID ARTHRITIS IS ASSOCIATED WITH INCREASED RISK OF ADVERSE CARDIOVASCULAR EVENTS INDEPENDENT OF MYOCARDIAL ISCHEMIA
Pires J, Oikonomou E, Agarwal R, Liu Y, miller E, Sinusas A, Feher A. IN PATIENTS UNDERGOING NUCLEAR MYOCARDIAL PERFUSION IMAGING, RHEUMATOID ARTHRITIS IS ASSOCIATED WITH INCREASED RISK OF ADVERSE CARDIOVASCULAR EVENTS INDEPENDENT OF MYOCARDIAL ISCHEMIA. Journal Of The American College Of Cardiology 2023, 81: 1467. DOI: 10.1016/s0735-1097(23)01911-3.Peer-Reviewed Original Research
2024
The Updated Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT 2.0).
Miller R, Lemley M, Shanbhag A, Ramirez G, Liang J, Builoff V, Kavanagh P, Sharir T, Hauser M, Ruddy T, Fish M, Bateman T, Acampa W, Einstein A, Dorbala S, Di Carli M, Feher A, Miller E, Sinusas A, Halcox J, Martins M, Kaufmann P, Dey D, Berman D, Slomka P. The Updated Registry of Fast Myocardial Perfusion Imaging with Next-Generation SPECT (REFINE SPECT 2.0). Journal Of Nuclear Medicine 2024, jnumed.124.268292. PMID: 39362762, DOI: 10.2967/jnumed.124.268292.Peer-Reviewed Original ResearchCoronary artery calciumCT attenuation correction imagesStress total perfusion deficitMyocardial perfusion imagingTotal perfusion deficitAttenuation correction imagesPerfusion imagingREFINE SPECTImprove prediction of adverse outcomesPerfusion deficitsSPECT myocardial perfusion imagingIncreased risk of MACEPredictive of adverse outcomesMedian follow-upInvasive coronary angiographyRisk of MACEAdverse cardiovascular eventsCAC scoreExperience MACECoronary angiographyArtery calciumInternational registryCardiovascular eventsFollow-upClinical dataContrast‐enhanced computed tomography for ex vivo assessment of human kidneys: A proof‐of‐concept study
Feizi A, DiRito J, Richfield O, Stendahl J, Harris M, Spindler S, Edwards C, Lysyy T, Lee S, Boutagy N, Feher A, Yoo P, Hosgood S, Mulligan D, Nicholson M, Sinusas A, Haakinson D, Tietjen G. Contrast‐enhanced computed tomography for ex vivo assessment of human kidneys: A proof‐of‐concept study. Artificial Organs 2024 PMID: 39189738, DOI: 10.1111/aor.14840.Peer-Reviewed Original ResearchContrast-enhanced computed tomographyNormothermic perfusionComputed tomographyHuman kidneyLocal informationAnalysis of biopsiesAssess organ functionNovel therapeutic strategiesEx vivo assessmentWhole organ perfusionProof-of-concept studyEx vivo perfusionInfusion scansAnatomical structuresOrgan perfusionThe Updated REgistry of Fast Myocardial Perfusion Imaging With NExt Generation SPECT
Miller R, Lemley M, Shanbhag A, Bednarski B, Liang J, Builoff V, Kavanagh P, Sharir T, Hauser M, Ruddy T, Fish M, Einstein A, Dorbala S, Di Carli M, Feher A, Miller E, Sinusas A, Halcox J, Martins M, Kaufmann P, Dey D, Berman D, Slomka P. The Updated REgistry of Fast Myocardial Perfusion Imaging With NExt Generation SPECT. Journal Of Nuclear Cardiology 2024, 38: 101926. DOI: 10.1016/j.nuclcard.2024.101926.Peer-Reviewed Original ResearchMulti-modality imaging for assessment of the microcirculation in peripheral artery disease: Bench to clinical practice
Callegari S, Feher A, Smolderen K, Mena-Hurtado C, Sinusas A. Multi-modality imaging for assessment of the microcirculation in peripheral artery disease: Bench to clinical practice. American Heart Journal Plus Cardiology Research And Practice 2024, 42: 100400. PMID: 38779485, PMCID: PMC11108852, DOI: 10.1016/j.ahjo.2024.100400.Peer-Reviewed Original ResearchPeripheral arterial diseaseMicrovascular diseasePeripheral microcirculationArtery diseaseEvaluation of response to therapyResponse to therapyManagement of peripheral arterial diseaseImprove risk stratificationOutcomes of peripheral artery diseaseAssessment of perfusionPathophysiology of peripheral arterial diseaseRisk of mortalityMolecular imaging studiesMulti-modal imagesPredictors of amputationRisk stratificationPre-clinicalImaging studiesClinical perfusionProcedural treatmentsClinical practicePersonalized managementMicrocirculationDiseasePerfusionA COMPARATIVE ANALYSIS OF PET, CZT SPECT, AND CONVENTIONAL SPECT IN MODERN CARDIOLOGY
Ahmed A, Agarwal R, Khera R, Liu Y, Sinusas A, Miller E, Feher A. A COMPARATIVE ANALYSIS OF PET, CZT SPECT, AND CONVENTIONAL SPECT IN MODERN CARDIOLOGY. Journal Of The American College Of Cardiology 2024, 83: 1365. DOI: 10.1016/s0735-1097(24)03355-2.Peer-Reviewed Original ResearchArtificial Intelligence Predicts Hospitalization for Acute Heart Failure Exacerbation in Patients Undergoing Myocardial Perfusion Imaging
Feher A, Bednarski B, Miller R, Shanbhag A, Lemley M, Miras L, Sinusas A, Miller E, Slomka P. Artificial Intelligence Predicts Hospitalization for Acute Heart Failure Exacerbation in Patients Undergoing Myocardial Perfusion Imaging. Journal Of Nuclear Medicine 2024, 65: jnumed.123.266761. PMID: 38548351, PMCID: PMC11064832, DOI: 10.2967/jnumed.123.266761.Peer-Reviewed Original ResearchConceptsMyocardial perfusion imagingHF hospitalizationHeart failureStress left ventricular ejection fractionPerfusion imagingHF exacerbationPredictive of HF hospitalizationsSPECT/CT myocardial perfusion imagingMyocardial perfusionInternational cohortAcute heart failure exacerbationMedian follow-upVentricular ejection fractionReceiver-operating-characteristic curveClinical risk factorsHeart failure exacerbationExternal validation cohortAcute HF exacerbationPrevent HF hospitalizationsImaging parametersCalcium scoreEjection fractionClinical parametersCT scanValidation cohort
2021
57884 Fast strain-encoded cardiac magnetic resonance detects immune checkpoint inhibitor associated cardiotoxicity
Cuomo J, Ragheb E, Feher A, Kwan J, Huber S, Mojibian H, Peters D, Sinusas A, Baldassarre L. 57884 Fast strain-encoded cardiac magnetic resonance detects immune checkpoint inhibitor associated cardiotoxicity. Journal Of Clinical And Translational Science 2021, 5: 141-142. PMCID: PMC8827987, DOI: 10.1017/cts.2021.761.Peer-Reviewed Original ResearchImmune checkpoint inhibitorsVentricular ejection fractionLV strainCardiotoxicity groupCheckpoint inhibitorsEjection fractionProspective studyCardiac functionNormal left ventricular ejection fractionLeft ventricular ejection fractionCardiac magnetic resonance imagingCardiac magnetic resonance imaging techniquesGlobal longitudinal LV strainAbnormal troponin valuesEvidence of cardiotoxicityProportion of myocardiumLarge prospective studiesLongitudinal LV strainStudy of patientsSteady-state free precession cine imagesAbnormal cardiac functionCircumferential LV strainT2-weighted imagingMagnetic resonance imagingDysfunctional segments
2020
IMPAIRED CORONARY FLOW RESERVE ON 82RUBIDIUM POSITRON EMISSION TOMOGRAPHY IMAGING PREDICTS ADVERSE EVENTS IN PATIENTS WITH AUTOIMMUNE DISEASE
Feher A, Boutagy N, Oikonomou E, Miller E, Sinusas A, Hinchcliff M. IMPAIRED CORONARY FLOW RESERVE ON 82RUBIDIUM POSITRON EMISSION TOMOGRAPHY IMAGING PREDICTS ADVERSE EVENTS IN PATIENTS WITH AUTOIMMUNE DISEASE. Journal Of The American College Of Cardiology 2020, 75: 1726. DOI: 10.1016/s0735-1097(20)32353-6.Peer-Reviewed Original Research
2019
Application of Hybrid Matrix Metalloproteinase-Targeted and Dynamic 201Tl Single-Photon Emission Computed Tomography/Computed Tomography Imaging for Evaluation of Early Post-Myocardial Infarction Remodeling
Thorn SL, Barlow SC, Feher A, Stacy MR, Doviak H, Jacobs J, Zellars K, Renaud JM, Klein R, deKemp RA, Khakoo AY, Lee T, Spinale FG, Sinusas AJ. Application of Hybrid Matrix Metalloproteinase-Targeted and Dynamic 201Tl Single-Photon Emission Computed Tomography/Computed Tomography Imaging for Evaluation of Early Post-Myocardial Infarction Remodeling. Circulation Cardiovascular Imaging 2019, 12: e009055. PMID: 31707811, PMCID: PMC7250243, DOI: 10.1161/circimaging.119.009055.Peer-Reviewed Original ResearchConceptsMyocardial blood flowSingle photon emissionBlood flowRecombinant TIMP-3Matrix metalloproteinasesR injuryTomography/Intracoronary deliveryMMP activationPost-myocardial infarction remodelingSubsequent left ventricular remodelingHybrid single-photon emissionDual-isotope single-photon emissionTomography/Computed Tomography ImagingLeft ventricular remodelingIschemia/reperfusionPost-MI remodelingPost-myocardial infarctionComputed tomography (CT) imagingIntracoronary infusionVentricular functionSaline groupVentricular remodelingNoninvasive evaluationTreatment groupsNoninvasive In Vivo Quantification of Adeno-Associated Virus Serotype 9–Mediated Expression of the Sodium/Iodide Symporter Under Hindlimb Ischemia and Neuraminidase Desialylation in Skeletal Muscle Using Single-Photon Emission Computed Tomography/Computed Tomography
Boutagy NE, Ravera S, Papademetris X, Onofrey JA, Zhuang ZW, Wu J, Feher A, Stacy MR, French BA, Annex BH, Carrasco N, Sinusas AJ. Noninvasive In Vivo Quantification of Adeno-Associated Virus Serotype 9–Mediated Expression of the Sodium/Iodide Symporter Under Hindlimb Ischemia and Neuraminidase Desialylation in Skeletal Muscle Using Single-Photon Emission Computed Tomography/Computed Tomography. Circulation Cardiovascular Imaging 2019, 12: e009063. PMID: 31296047, PMCID: PMC6629470, DOI: 10.1161/circimaging.119.009063.Peer-Reviewed Original ResearchConceptsMicro-single photon emissionSingle photon emissionHindlimb ischemiaTomography/Tomography/Computed TomographyIschemic gastrocnemius muscleNIS inhibitor perchloratePeripheral artery diseaseSkeletal muscleUnilateral hindlimb ischemiaAdeno-Associated Virus Serotype 9Standardized uptake valueSodium/iodide symporterVivo quantificationVirus serotype 9Vivo validationNonischemic limbsArtery diseaseNonischemic muscleC57BL/6J miceMurine modelGastrocnemius muscleComputed tomographyIschemic conditionsRadiotracer uptake