2023
Attenuation correction for PET imaging using conditional denoising diffusion probabilistic model
Dong Y, Jang S, Han P, Johnson K, Ma C, Fakhri G, Li Q, Gong K. Attenuation correction for PET imaging using conditional denoising diffusion probabilistic model. 2023, 00: 1-1. DOI: 10.1109/nssmicrtsd49126.2023.10338188.Peer-Reviewed Original ResearchDiffusion probabilistic modelGenerative adversarial networkConditional encodingAttenuation correctionDenoising diffusion probabilistic modelLow-level featuresProbabilistic modelAttenuation coefficientAdversarial networkExtract featuresPET/MR systemsEncodingPET acquisitionNovel methodDiffusion encodingMagnetic resonanceImagesPET imagingCorrectionMR imagingUNetAttenuationNetworkFeaturesResonance
2021
Free‐breathing 3D cardiac T1 mapping with transmit B1 correction at 3T
Han P, Marin T, Djebra Y, Landes V, Zhuo Y, Fakhri G, Ma C. Free‐breathing 3D cardiac T1 mapping with transmit B1 correction at 3T. Magnetic Resonance In Medicine 2021, 87: 1832-1845. PMID: 34812547, PMCID: PMC8810588, DOI: 10.1002/mrm.29097.Peer-Reviewed Original ResearchConceptsFlip-angle estimationCardiac T<sub>1</sub> mappingGradient echo readoutThrough-plane spatial resolutionImaging timePractical imaging timesFree breathingPhantom studyB1 correctionAccelerated imagingIn-planeT)-spaceMyocardial T<sub>1</sub> valuesSubspace-based methodsSpatial resolutionImaging experimentsAcquisition schemeT)-space dataSubject-specific timeCorrectionModified Look-Locker inversion recoveryLook-Locker inversion recoveryTime of data acquisitionAverage imaging timeInversion-recovery sequence
2020
Attenuation correction using deep Learning and integrated UTE/multi-echo Dixon sequence: evaluation in amyloid and tau PET imaging
Gong K, Han P, Johnson K, El Fakhri G, Ma C, Li Q. Attenuation correction using deep Learning and integrated UTE/multi-echo Dixon sequence: evaluation in amyloid and tau PET imaging. European Journal Of Nuclear Medicine And Molecular Imaging 2020, 48: 1351-1361. PMID: 33108475, PMCID: PMC8411350, DOI: 10.1007/s00259-020-05061-w.Peer-Reviewed Original ResearchConceptsAttenuation correctionResultsThe Dice coefficientPseudo-CT imagesMR-based AC methodsAccurate ACAC accuracyPET imagingDice coefficientQuantitative accuracyAtlas methodAC methodGradient echoNear verticesTau imagingTau PET imagingAlzheimer's diseaseUltrashortCorrectionTau pathologyRapid acquisitionDeep learning methodsMonitoring of Alzheimer’s diseasePET/MRAmyloidMR‐based PET attenuation correction using a combined ultrashort echo time/multi‐echo Dixon acquisition
Han P, Horng D, Gong K, Petibon Y, Kim K, Li Q, Johnson K, Fakhri G, Ouyang J, Ma C. MR‐based PET attenuation correction using a combined ultrashort echo time/multi‐echo Dixon acquisition. Medical Physics 2020, 47: 3064-3077. PMID: 32279317, PMCID: PMC7375929, DOI: 10.1002/mp.14180.Peer-Reviewed Original ResearchConceptsLinear attenuation coefficientPositron emission tomography attenuation correctionPhysical compartmental modelAttenuation correctionShort T<sub>2</sub> componentPET attenuation correctionRadial k-space trajectoryMagnetic resonance (MR)-based methodK-space trajectoriesRadial trajectoryK-spaceAttenuation coefficientDixon acquisitionsPositron emission tomographyWhole white matterMuting methodImage reconstructionImaging speedMR signalMRAC methodPositron emission tomography imagingCorrectionGray matter regionsPhantomMatter regions
2019
Bulk motion detection and correction using list-mode data for cardiac PET imaging
Sun T, Petibon Y, Han P, Ma C, Kim S, Alpert N, Fakhri G, Ouyang J. Bulk motion detection and correction using list-mode data for cardiac PET imaging. Proceedings Of SPIE--the International Society For Optical Engineering 2019, 11072: 110722f-110722f-5. DOI: 10.1117/12.2534701.Peer-Reviewed Original ResearchList-mode dataCardiac PET imagingPET list-mode dataMotion-corrected imagesLines of responsePET imaging applicationsCardiac PETImage qualityBulk motionCardiac PET studiesMotion correctionPET imagingBrain PETMotion estimationData-driven approachMotion detectionImaging applicationsImage spaceMoving frameStatic reference frameMotion transformationCorrectionCenter positionMotionReference frame
2016
DC artifact correction for arbitrary phase-cycling sequence
Han P, Park H, Park S. DC artifact correction for arbitrary phase-cycling sequence. Magnetic Resonance Imaging 2016, 38: 21-26. PMID: 27998747, DOI: 10.1016/j.mri.2016.12.015.Peer-Reviewed Original Research